AquaStar GWH 1600 P Spécifications

Naviguer en ligne ou télécharger Spécifications pour Chauffe-eau et chaudières AquaStar GWH 1600 P. AquaStar GWH 1600 P Specifications Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 48
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
6720607072-00.1 JS
GWH-635-ES-N - Natural Gas
GWH-635-ES-L - Liquefied Petroleum (LP) Gas
Warning: If the information in this manual is not
followed exactly, a fire or explosion may result
causing property damage, personal injury or death.
Do not store or use gasoline or other flammable
vapor and liquids in the vicinity of this or any other
appliance.
Improper installation, adjustment, alteration,
service or maintenance can cause injury or
property damage. Refer to this manual. For
assistance or additional information consult a
qualified installer, service agency or the gas
supplier.
In the Commonwealth of Massachusetts this
product must be installed by a licensed plumber or
gas fitter.
Upon completion of the installation, these
instructions should be handed to the user of the
appliance for future reference.
What to do if you smell gas
Close gas valve. Open windows.
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire
department.
Installation and service must be performed by a
qualified installer, service agency or the gas supplier.
Vue de la page 0
1 2 3 4 5 6 ... 47 48

Résumé du contenu

Page 1 - GWH-635-ES-N - Natural Gas

6720607072-00.1 JSGWH-635-ES-N - Natural GasGWH-635-ES-L - Liquefied Petroleum (LP) GasWarning: If the information in this manual is notfollowed exact

Page 2 - 2 1 Warning

Installation instructionsFuel Gas Code. Consult a HVAC specialist if your airinfiltration rate is questionable.The space must have two permanent openi

Page 3 - 6 720 608 108 3

Installation instructions3.6Ventingpermitted in the total vent length), or subtract 11/4feet for every 45 ° elbow used. Horizontal sections ofvent mus

Page 4 - 2 Appliance details

Installation instructionsand may result in a hazardous condition. For specificquestions concerning vent material, specifications,usage or installation

Page 5 - The box includes:

installation instructions3,6.3 Condensate drain tube requirementsExhaust collar condensate drain installation(supplied with heater)• The condensate dr

Page 6

Installation instructionsa 3" or 4" pipe from the outside. See Chapter 3.5 formore direction on combustion air.• To reduce pressure differen

Page 7 - _--_--_ _os

Installation instructionsOver 20/12 to 21/12 8.0 2.44Table 5 Termh_ation heights at various roof pitchesInterior masonry chimneysThe single wall stain

Page 8 - 3 Installation instructions

Installation instructionsEQUIPMENT VENTING SYSTEM REQUIRED.When the manufacturer of Product Approved sidewall horizontally mounted gas equipment provi

Page 9

Installation instructionsRecommended exhaust vent terminator clearancesFig. 17Description Minimum distanceDirectly below an opening; operable windows,

Page 10 - 10 6 720 608 108

Installation instructions3,6.7 Exhaust vent configuration examplesSupporting the exhaust vent systemMI_IMUM ABOV GR©U DRAIN CAP _.FLASHINGSTORM COLLAR

Page 11 - Ventlengths

Installation instructions3.7 Gas piping & connections ]_!Before connecting the gas supply, check the ratingplate on the right side of the heater t

Page 12 - 6 720 608 108

IndexIndexWarning2 Appliance details2.1 Features2.2 GWH-635=ES Specifications (Technical data)2.3 Unpacking the GWH-635-ES heater2.4 General rules to

Page 13 - (supplied with heater)

Installation instructionsFOR NATURAL GASMaximum Capacity of pipe in Cubic Feet of Gas per Hour for Gas Pressure of 0.5 Psig or less and a Pressure dro

Page 14 - Vent terminations

Installation instructions3.8 Measuring gas pressureConfirm proper gas pressure upon installation.Connecting Manometer• Shut off gas supply at installe

Page 15 - 3.6.6 Horizontal terminations

Installation instructions3.9 Water connections• When facing the heater, the 3/4"cold inlet connectionis on the bottom right and the hot connectio

Page 16

Installation instructions3.10 Electrical connectionsThe GWH-635-ES requires an electrical power supplyfrom a 120VAC / 60Hz circuit (with a dedicated o

Page 17

Operation instructions4Operation instructions°©\42)Fig. 281 On/Off switch2 Resetbutton3 Program" _ " button4 Increasingtemperatureselector5

Page 18

Operation instructionsOff• To shut down the appliance move the on/off switch tothe "off" position (0),4.3 Temperature selectionTo select out

Page 19

Operation instructionsSetting the water temperatureThe desired temperature of the hot water can be adjusted on the front control panel of the heater.T

Page 20 - FOR LP GAS

Operation instructions4.4 Use of optional remote controlaccessory• press reset button in order to return heater to normaloperation.Fig. 32 Remote cont

Page 21 - 3.8 Measuring gas pressure

Maintenance and service5 Maintenance and serviceThe unit should be checked once a year by a gastechnician. If repairs are needed, the repairs should b

Page 22 - 3.9 Water connections

Maintenance and service5.3 Mineral scale build-upPeriodic descaling may be necessary in areas with highmineral content in the water. Scale buildup in

Page 23 - 3.11 Cascading function

WarningOperation is subject to the following two conditions: (1)This device may not cause harmful interference, and (2)this device must accept any int

Page 24 - Operation instructions

Maintenance and serviceFig. 40 Measuring port• While holding the Program (P) button, turn the ON/OFF switch to ON (I) position (see Fig. 41). As soona

Page 25 - 4.3 Temperature selection

Maintenance and serviceFig. 43 Adjusting P2 CO 2 level3. Verify both P1 and P2 CO 2 readings are within theranges specified in table 10. Repeat steps

Page 26

Maintenance and service5.5 Control board diagnostics1. Turn on/off switch on water heater to off (O) position.2. Press and hold the program ( <Zb )

Page 27

Troubleshooting6 Troubleshooting6.1 IntroductionMany of the questions customers ask regardingoperation of this unit can be answered by following thetr

Page 28 - 5 Maintenance and service

Troubleshooting7. Cold water is mixing into the hot water lines(plumbing crossover). A plumbing crossover canunintentionally mix cold water with the h

Page 29 - 5.4 Adjusting CO 2

Troubleshooting2. Improper venting. Venting that is unsealed, the wrongmaterial, too big in diameter or too long in run willresult in unstable burner

Page 30 - 30 6 720 608 108

Troubleshooting6.8 Error code diagnosticsPart numbers subject to change.A2A7Fault in the flue gas limiter (part#8700400032).Note: Old style overheat c

Page 31 - P2 CO 2 Reading: _% 002

Troubleshooting(31C6C7CAFan rotation too low on star[up.(part# 8707204039)Fan rotation too low in operation(part# 8707204039)No rotational speed senso

Page 32 - 5.5 Control board diagnostics

TroubleshootingE1E2E9Over-temperature detected by temperaturesensor on hot water pipe.(part# 8700400015)Cold water temperature sensor fault.(part# 870

Page 33 - 6 Troubleshooting

TroubleshootingEAECEONo flame ionization detected with waterflow.(part# 8708107020)Ionization failure during operation.(part# 8708107020)Internal hard

Page 34 - 34 6 720 608 108

Appliance details2 Appliance details2.1 FeaturesParts• Touch pad interface control• High power pre-mix compact burner with low NOxemissions• Modulatin

Page 35

TroubleshootingF7FA8EIonization error at standby.(part# 8708107020)Gas leakage error, gas valve circuit notclosing properly.(part# 8707021019)Electron

Page 36 - 6.8 Error code diagnostics

7 Electrical diagramFig, 44 Electrica/ scheme1 Intlet water temperature sensor2 Ionization sensor3 Water flow sensor4 Flue gas limiter5 Temperature li

Page 37 - Table 12

GWH-635-ES Functional scheme8 GWH-635-ES Functional schemeIDLEYESYES NOYESNO NO _ NONO YES YESYESHot waterdelivered atselected temp.ESYES#Fig. 45 Func

Page 38

Interior components diagram and parts list9 Interior components diagram and parts list9.1 Interior componentsFig. 46 Components1 Cover2 On/Off switch3

Page 39

Interior components diagram and parts list9.2 Components diagram334524Fig. 48 Components Diagram44t918222628296720607072-34.8 JF44 6 720 608 108

Page 40 - 40 6 720 608 108

Interior components diagram and parts list9.3 Parts list123456789lO11121314151617181920212223242526272829303132333435363738394042434445464748Table 13F

Page 41 - 7 Electrical diagram

Protecting the environment10 Protecting the environmentPackingThe packing box may be fully recycled as confirmed bythe recycling symbol z'_Compon

Page 42 - 42 6 720608 108

Fifteen Year Limited Warranty11 Fifteen Year Limited WarrantyGeneralBOSCH PRO tankless water heaters are warranted bythe Manufacturer (BOSCH) through

Page 43 - 9.1 Interior components

Installer Checklist, to be performed by installer upon installationSerial NumberGas Pressure Reading _Building Water PressureInstalling CompanyInstall

Page 44 - 9.2 Components diagram

Appliance details• CO 2 level set from factory, see chapter 5.4.Dimensions• Depth (in): 8 V2" (220 ram)• Width (in): 15 3/4" (400 ram)• Heig

Page 45 - 9.3 Parts list

Appliance details2.4 General rules to follow for safeoperation• 1. You must follow these instructions when youinstall your heater. In the United State

Page 46 - 10 Protecting the environment

Appliance details2.5 Dimensions and Minimum installation clearancesFig. 4 Dimensions1 Cover2 On/Off switch3 Reset button4 LCD display5 Program button6

Page 47 - 6 720 608 108 47

Installation instructions3 Installation instructions3.1 IntroductionPlease follow these instructions. Failure to followinstructions may result in:• Da

Page 48 - Bosch Group

Installation instructionspitch down towards termination 1/4inch for every foot ofhorizontal length.Single pipe method:Although it is permissible to dr