WARNING: Improper installation, adjustment,
alteration, service or maintenance can cause injury
or property damage. Refer to this manual. For
assistance or additional information consult a
qualified installer, service agency or the gas supplier.
Upon completion of the installation, these instructions
should be handed to the user of the appliance for
future reference.
FEATURING: Automatic Variable Power Modulating Gas
Valve
INSTALLATION AND OPERATING INSTRUCTIONS FOR AUTOMATIC
INSTANTANEOUS TYPE WATER HEATERS FOR USE WITH NATURAL AND
LIQUEFIED PETROLEUM GAS
MODEL 125B LP and 125B NG (Flow Modulated)
Suitable for water (potable) heating and space heating
Intended for variable flow applications with steady cold water inlet temperatures. For preheated domestic
hot water, install the 125 BS model. For recirculating applications, install the 125 BL model.
WARNING
If the information in this manual is not followed exactly,
a fire or explosion may result causing property
damage, personal injury or death.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable,
combustible or corrosive vapors and liquids in the
vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
- Do not try to light any appliance.
- Do not touch any electrical switch; do not use any
phone in your building.
- Immediately call your gas supplier from a neighbors
phone. Follow the gas suppliers instructions.
- If you cannot reach your gas supplier, call the fire
department.
- Installation and service must be performed by a
qualified installer, service agency or the gas supplier.
Specifications .................................................... Page 2
Rules for safe operation .................................... Page 4
Locating the Heater ........................................... Page 5
Combustion Air Requirements ........................... Page 5
Mounting the Heater .......................................... Page 6
Venting the Heater ............................................. Page 6
Gas Connections ............................................... Page 7
Water Connections ............................................ Page 8
Safety before lighting the pilot............................ Page 8
Lighting instructions ........................................... Page 9
Setting water temperature ................................. Page 9
Maintenance & Service ...................................... Page 9
Trouble Shooting ............................................. Page 10
Diagram of AquaStar ....................................... Page 13
Components and Parts List ............................. Page 14
TABLE OF CONTENTS
6 720 605 297 PT 862 (12.98)
Vue de la page 0
1 2 3 4 5 6 ... 15 16

Résumé du contenu

Page 1 - LIQUEFIED PETROLEUM GAS

WARNING: Improper installation, adjustment,alteration, service or maintenance can cause injuryor property damage. Refer to this manual. Forassistanc

Page 2 - UNPACKING THE AQUASTAR HEATER

10TROUBLE SHOOTINGIntroductionThe AquaStar 125 burners are activated by a water flowvalve. Numerous water related problems can cause thiswater valve t

Page 3 - FRONT VIEW SIDE VIEW

116. Faulty thermocouple (part #8747202083) orelectromagnet ) Unless these 2 parts are at least 8to 10 years old, it is very unlikely that they are fa

Page 4

12PILOT LIGHT GOES OUT DURING OR IMMEDIATELYAFTER HOT WATER HAS BEEN USED1. Gas pressure too lowVery low gas pressure may be caused by low deliveredga

Page 5 - COMBUSTION AIR REQUIREMENTS

13Fig. 11 - Diagram of AquaStar 125 B 511 14910 1. Heat exchanger 2. Pilot assembly 3. Burner manifold gaspressure test nipple 4. Main gas burner

Page 6 - CLEARANCES

14Fig. 12 - INTERIOR COMPONENTS DIAGRAM AND PARTS LIST

Page 7 - GAS LINE SIZE

15Fig. 12INTERIOR COMPONENTS DIAGRAMAND PARTS LIST 125B1 Cover ¤ 8 705 421 0252 Plastic collar ¤ 8 700 403 0083 Temperature adjustment knob ¤ 8 702

Page 8 - WATER CONNECTIONS

Replacement Parts available from North American DistributorCONTROLLED ENERGY CORP.340 Mad River ParkVermont 05673 (U.S.A.)Phone 800-642-3111Fax (802)

Page 9 - MAINTENANCE AND SERVICE

2This well engineered, gas water heater has all the fea-tures a water heater should have:It operates on the principle of heating water instantaneously

Page 10 - TROUBLE SHOOTING

3D861_059MINIMUM INSTALLATION CLEARANCES FROM COMBUSTIBLE ANDNON COMBUSTIBLE MATERIALS FOR ALCOVE INSTALLATIONSFRONT VIEW SIDE VIEWAQUASTAR MODELS 125

Page 11

4If you are using the AquaStar for combined space heating and potable water heating (seeschematic diagram below), all piping and other components conn

Page 12

54. You must vent your heater. See section on Vent PipeConnections, Page 5.5. The appliance must be disconnected from the gassupply piping system duri

Page 13 - Diagram of AquaStar 125 B

6CLEARANCESThe Aquastar 125 B is design certified for installation on acombustible wall and for installation in an alcove with theminimum clearances t

Page 14

7The flue connection for the AquaStar 125B is 5 inches.However, in Canada, for installations at high altitude (2000-4500 feet above sea level) a six i

Page 15

8OPERATING INSTRUCTIONSBefore proceeding with the operation of the heater makesure that the system is filled with water.Make sure the water heater dra

Page 16 - INSTALLATION CHECKLIST

9LIGHTING INSTRUCTIONS1. STOP! Read the safety information above on this plate.2. The Gas valve must be turned off by sliding the gasvalve button to t